Dimplex IgniteXL Linear Electric Fireplace Size Guide

Framing dimensions, electrical requirements, and clearance guidelines for the Dimplex IgniteXL (XLF50, XLF60, XLF74, XLF100) to help contractors and homeowners plan the installation.

πŸ“‹

Overview

What this guide covers and how to use it

The Dimplex IgniteXL is a recessed linear electric fireplace available in four widths: 50", 60", 74", and 100". It installs into a standard framed wall opening with no venting, no gas line, and no chimney. All models support both 120V and 240V hardwired electrical connections.

This guide covers the framing dimensions, electrical requirements, and clearance guidelines you need before ordering or beginning installation. For full product details, pricing, and availability, see the Dimplex IgniteXL product page. To compare the IgniteXL against other Dimplex electric fireplace series, see the Dimplex comparison guide.

ℹ️

All four sizes covered

This guide includes confirmed framing, overall, and viewing area dimensions for all four IgniteXL models: 50" (XLF50), 60" (XLF60), 74" (XLF74), and 100" (XLF100). All values are from the Dimplex installation documentation for each size.

πŸ—οΈ

Installation Types

All dimensions from the Dimplex installation manual

The IgniteXL supports two installation configurations, determined by the depth of the wall framing:

Partially Recessed β€” 2Γ—4 Wall (3-1/2" framing depth)

When installed in a standard 2Γ—4 partition wall, the unit sits partially recessed with a portion of the firebox extending beyond the wall face. A trim kit (sold separately, model X-XLFTRIM50 for the 50" unit) is recommended to cover the gap between the fireplace face and the finished wall surface. This configuration is suitable for drywall and tile finishes.

Flush-Mounted β€” 2Γ—6 Wall (5-1/2" framing depth)

A 2Γ—6 framed wall allows the unit to sit fully flush with the wall surface for a clean, edgeless installation. Trim is optional in this configuration. The unit installs without trim to stone, brick, and other solid finish materials; the included trim is used for drywall and tile surfaces.

⚠️ Load-Bearing Warning

This fireplace is NOT load-bearing. Ensure the opening is framed so that the weight of building materials does not create pressure on the top of the fireplace. Two people are required for installation.

⚠️ Decorative Finish Overhang Limit

Decorative finishing material, such as brick, must be limited to Β½" (1.3 cm) of overhang over the fireplace opening to ensure adequate flow of heated air out of the firebox area.

Wiring Entry Location

The wiring entry point is located on the right side at the bottom of the firebox. Plan the framing to allow routing of the power cable to this location before the wall is closed.

Serviceable from the Front

All internal components are replaceable from the front of the fireplace while the unit is mounted in the wall. No rear access is required for future servicing.

⚑

Electrical Requirements

All electrical values from the Dimplex installation manual β€” XLF50 only

The IgniteXL supports hardwired connection at 120V or 240V. The voltage configuration affects heat output and amperage draw but does not change the framing or rough opening dimensions. Select the voltage based on circuit availability and desired heat output.

XLF50 β€” Electrical Specifications

Specification 120V Configuration 240V Configuration
Voltage 120V 240V
Wattage 1,500W 2,500W
BTU Output 5,118 BTU 8,530 BTU
Amperage 12.5A 10.4A
Connection Type Hardwire Hardwire
Framing dimensions Identical for both voltages β€” see Size-by-Size Reference
ℹ️

120V vs. 240V β€” same rough opening, different heat

The framing and rough opening dimensions are identical regardless of whether you choose 120V or 240V wiring. The difference is heat output only: 240V delivers 2,500W (8,530 BTU) vs. 1,500W (5,118 BTU) at 120V. Plan your circuit before installation β€” switching voltage after the wall is closed requires re-wiring.

XLF60, XLF74, XLF100 β€” Electrical Specifications

All four IgniteXL models share identical electrical specifications. The voltage and wattage ratings are the same across the 50", 60", 74", and 100" models. Select the voltage based on circuit availability and desired heat output.

🌿

Outdoor installations

For outdoor installations, a ground-fault protected circuit is recommended. All electrical connections and routings must comply with local building code requirements. See the Clearances & Safety section for outdoor overhang rules.

πŸ“

Clearances & Safety

Installation clearance guidelines from the Dimplex installation manual

Television and Overhanging Objects

For overhanging temperature-sensitive objects β€” such as a television, mantel, or artwork β€” always follow the recommendations provided by that object's manufacturer for installation over a heater. The Dimplex installation manual provides a heat zone chart for the area above the fireplace, describing three zones:

  • The zone immediately above the unit (within approximately 10–12 inches height and 1–4 inches depth from the glass) is subject to temperatures exceeding 65Β°C (149Β°F).
  • A broader surrounding zone is subject to temperatures exceeding 40Β°C (104Β°F).
  • Areas sufficiently above and away from the unit fall below 40Β°C (104Β°F).

No single minimum clearance number is stated in the installation manual. The manufacturer directs installers to the overhang manufacturer's own installation guidelines. Consult a qualified installer if you are unsure whether your planned overhang is within safe temperature range.

⚠️

Side, rear, bottom, and ceiling clearances

Specific clearance values for sides, rear, bottom, and ceiling are not published in the Dimplex installation documentation. Install per the manufacturer's complete installation instructions. If clearance values are required for a permit or local code compliance, contact Dimplex directly or consult a licensed installer before beginning construction.

Outdoor Installation β€” Overhang Requirements

The IgniteXL is approved for outdoor installation in areas sheltered by an overhang that protects against direct water ingress. To maintain warranty coverage, the overhang must satisfy the following relationship:

Maximum Height ≀ 3 Γ— Projection Length

  • Maximum Height β€” measured vertically from the bottom of the fireplace to the bottom edge of the overhang
  • Projection Length β€” measured from the exposed face of the fireplace to the parallel edge of the overhang

The installation manual specifies the overhang must be more than 24 inches above the bottom of the fireplace and extend more than 5 inches outward. For example: if the overhang is 9 feet above the bottom of the fireplace, it must extend at least 3 feet outward on all sides.

🌿

Outdoor warranty term

Indoor installations carry a 5-year limited warranty. Outdoor installations carry a 1-year limited warranty. Warranty coverage for outdoor installations requires the overhang to satisfy the dimensions above.

Overheating Protection

The IgniteXL has a built-in thermal cutoff that automatically shuts the unit off if the heater overheats. To reset: turn the unit off at the main disconnect panel and wait 5 minutes before turning it back on. If the heater requires repeated resets, turn off at the panel and contact Dimplex technical support.

πŸ”

Size-by-Size Reference

All dimensions from the Dimplex installation manual

50" Model β€” XLF50

XLF50 β€” Overall Unit Dimensions

XLF50 / UL: 6909630100

Dimensions of the physical unit as it ships. Depth is identical with or without trim.

Overall Width (no trim) 50-1/8" (127.2 cm)
Overall Height (no trim) 15-5/8" (39.6 cm)
Overall Depth 5-3/4" (14.6 cm)
Overall Width (with trim) 51-1/2" (130.6 cm)
Overall Height (with trim) 16-1/2" (41.9 cm)
Overall Depth (with trim) 5-3/4" (14.6 cm)

XLF50 β€” Framing & Rough Opening Dimensions

These are the dimensions of the framed wall opening the unit slides into. The depth depends on your wall construction. Framing width and height are the same for both 120V and 240V configurations.

Framing W 50-5/8" (128.6 cm)
Framing H 16" (40.6 cm)
Framing D β€” 2Γ—4 Wall 3-1/2" (9.0 cm)
Framing D β€” 2Γ—6 Wall 5-1/2" (14.0 cm)

XLF50 β€” Viewing Area

The visible flame window through the glass, measured across the front face of the unit.

Viewing Area W 48-3/4" (123.8 cm)
Viewing Area H 11-3/4" (29.7 cm)
View Dimplex IgniteXL pricing and availability β†’

60" Model β€” XLF60

XLF60 β€” Overall Unit Dimensions

XLF60 / UL: 6910000100

Dimensions of the physical unit as it ships. Depth is identical with or without trim.

Overall Width (no trim) 60" (152.2 cm)
Overall Height (no trim) 15-5/8" (39.6 cm)
Overall Depth 5-3/4" (14.6 cm)
Overall Width (with trim) 61-1/4" (155.5 cm)
Overall Height (with trim) 16-1/2" (41.9 cm)
Overall Depth (with trim) 5-3/4" (14.6 cm)

XLF60 β€” Framing & Rough Opening Dimensions

Framing width and height are the same for both 120V and 240V configurations.

Framing W 60-5/8" (154.0 cm)
Framing H 16" (40.6 cm)
Framing D β€” 2Γ—4 Wall 3-1/2" (9.0 cm)
Framing D β€” 2Γ—6 Wall 5-1/2" (14.0 cm)

XLF60 β€” Viewing Area

The visible flame window through the glass, measured across the front face of the unit.

Viewing Area W 58-3/4" (149.2 cm)
Viewing Area H 11-3/4" (29.7 cm)
View Dimplex IgniteXL pricing and availability β†’

74" Model β€” XLF74

XLF74 β€” Overall Unit Dimensions

XLF74 / UL: 6909690100

Dimensions of the physical unit as it ships. Depth is identical with or without trim.

Overall Width (no trim) 74-1/8" (188.4 cm)
Overall Height (no trim) 15-5/8" (39.6 cm)
Overall Depth 5-3/4" (14.6 cm)
Overall Width (with trim) 75-1/2" (191.6 cm)
Overall Height (with trim) 16-1/2" (41.9 cm)
Overall Depth (with trim) 5-3/4" (14.6 cm)

XLF74 β€” Framing & Rough Opening Dimensions

Framing width and height are the same for both 120V and 240V configurations.

Framing W 74-5/8" (189.7 cm)
Framing H 16" (40.6 cm)
Framing D β€” 2Γ—4 Wall 3-1/2" (9.0 cm)
Framing D β€” 2Γ—6 Wall 5-1/2" (14.0 cm)

XLF74 β€” Viewing Area

The visible flame window through the glass, measured across the front face of the unit.

Viewing Area W 72-3/4" (184.6 cm)
Viewing Area H 11-3/4" (29.7 cm)
View Dimplex IgniteXL pricing and availability β†’

100" Model β€” XLF100

XLF100 β€” Overall Unit Dimensions

XLF100 / UL: 6909700100

Dimensions of the physical unit as it ships. Depth is identical with or without trim.

Overall Width (no trim) 100-1/8" (254.2 cm)
Overall Height (no trim) 15-5/8" (39.6 cm)
Overall Depth 5-3/4" (14.6 cm)
Overall Width (with trim) 101-1/2" (257.6 cm)
Overall Height (with trim) 16-1/2" (41.9 cm)
Overall Depth (with trim) 5-3/4" (14.6 cm)

XLF100 β€” Framing & Rough Opening Dimensions

Framing width and height are the same for both 120V and 240V configurations.

Framing W 100-5/8" (255.7 cm)
Framing H 16" (40.6 cm)
Framing D β€” 2Γ—4 Wall 3-1/2" (9.0 cm)
Framing D β€” 2Γ—6 Wall 5-1/2" (14.0 cm)

XLF100 β€” Viewing Area

The visible flame window through the glass, measured across the front face of the unit.

Viewing Area W 98-3/4" (250.6 cm)
Viewing Area H 11-3/4" (29.7 cm)
View Dimplex IgniteXL pricing and availability β†’
❓

Frequently Asked Questions

All answers sourced from the Dimplex installation manual

What framing depth does the Dimplex IgniteXL require?

The IgniteXL requires a minimum framing depth of 3-1/2 inches for a 2Γ—4 wall (partially recessed installation) or 5-1/2 inches for a 2Γ—6 wall (flush-mounted installation). The 2Γ—4 option leaves a portion of the unit protruding from the wall; a trim kit is recommended to cover the gap. All dimensions are from the Dimplex installation manual.

What is the rough opening size for the Dimplex IgniteXL 50-inch model?

The XLF50 requires a framed opening of 50-5/8 inches wide by 16 inches tall. The framing depth is 3-1/2 inches for 2Γ—4 construction or 5-1/2 inches for 2Γ—6 construction. These dimensions are the same for both 120V and 240V electrical configurations. All dimensions are from the Dimplex installation manual.

Can the Dimplex IgniteXL be installed outdoors?

Yes. The IgniteXL is approved for outdoor installation in areas sheltered by an overhang that protects against direct water ingress. A ground-fault protected circuit is recommended for outdoor use. To maintain warranty coverage, the overhang height must not exceed three times the overhang projection length, and the overhang must be more than 24 inches above the bottom of the fireplace and extend more than 5 inches outward. The outdoor warranty term is 1 year; the indoor warranty term is 5 years.

Does the Dimplex IgniteXL require venting?

No. The IgniteXL is a non-venting electric fireplace. It requires no gas line, chimney, or flue of any kind. The only utility connection required is electrical.

What are the electrical requirements for the Dimplex IgniteXL?

All four IgniteXL models share identical electrical specifications. Each supports both 120V and 240V hardwired connections. At 120V the unit draws 1,500W (12.5 amps, 5,118 BTU). At 240V it draws 2,500W (10.4 amps, 8,530 BTU). The framing dimensions are identical regardless of voltage. Wiring entry is located on the right side at the bottom of the firebox on all models. All electrical values are from the Dimplex installation documentation.