Modern Flames Orion Slim Size Guide: 52"–100"

Framing dimensions, electrical requirements, and clearance specifications for all four Orion Slim models — sourced from the Modern Flames installation manual.

📋

Overview

Models OR52-SLIM through OR100-SLIM — key planning facts

The Orion Slim is available in four sizes: 52", 60", 76", and 100". All four models share a uniform overall height of 19-5/8" and overall depth of 6-5/16", and a uniform minimum framing depth of 6". Only width varies between sizes. All models operate on 120V only — no 240V option is available.

This guide documents the framing dimensions, electrical requirements, and clearances from the Modern Flames Orion Slim installation manual. All dimensions are stated in inches with millimeter equivalents as documented. For purchasing information, see the Orion Slim product page.

🏠

Not doing your own framing?

Send this page to your installer — they will know exactly how to use it. The key numbers they need: minimum wall depth is 6", the framing height is 19-1/8" for all four sizes, and a dedicated 20-amp circuit is required. Everything else on this page is for them.

ℹ️

6" minimum framing depth — all four models

The Orion Slim's 6" minimum framing depth is shallower than most linear fireplaces. A standard 2×6 framed wall (5-1/2" stud depth + drywall) may not meet this requirement — verify actual available cavity depth before ordering.

🔧

Installation Types

Three installation types supported per the installation manual

The Orion Slim supports three installation types, as stated in the installation manual: "Your appliance is a wall-mounted, recessed, and/or mantel installed appliance."

  • Wall Recessed (Slide-In): The unit slides into a framed wall opening. Requires a finished opening sized to the model-specific framing dimensions in this guide. This is the standard built-in configuration.
  • Wall Mounted (Surface): The unit mounts to the wall surface via the included bracket. Does not require recessing into the wall. The bracket must secure to a minimum of 2 studs.
  • Mantel Installation: Explicitly stated as supported in the installation manual. Specific mantel installation procedures are not detailed separately — follow manufacturer instructions.

⚠️ Freestanding Installation Prohibited

The installation manual states: "ALWAYS mount to wall bracket before use. DO NOT set on the floor, or other surface, to use." The Orion Slim must always be secured to a wall bracket — it cannot be used freestanding.

📐

Framing Requirements

All finished opening dimensions from the Modern Flames installation manual

Finished Opening Dimensions — All Models

Model Framing W Framing H Min. Framing D
OR52-SLIM 50-3/4"
(1289mm)
19-1/8"
(486mm)
6" min.
(152mm min.)
OR60-SLIM 58-1/2"
(1486mm)
19-1/8"
(486mm)
6" min.
(152mm min.)
OR76-SLIM 75-1/8"
(1908mm)
19-1/8"
(486mm)
6" min.
(152mm min.)
OR100-SLIM 99-1/2"
(2527mm)
19-1/8"
(486mm)
6" min.
(152mm min.)

Framing height (19-1/8") and minimum framing depth (6") are identical across all four models. Only framing width varies.

Electrical Requirements

All values apply equally to all four sizes — from the Modern Flames installation manual

Power Specifications — All Models

Specification Value
Voltage 120V AC, 60Hz
Wattage 1,465W
BTU output 5,000 BTU
Required circuit Dedicated 110–120V, 20-amp grounded
Required breaker 20 Amp or higher, dedicated
240V option Not available — 120V only
Extension cords Prohibited
Power strips Prohibited
Shared circuits Prohibited — dedicated circuit only

Wiring

  • Plug-in: Plug directly into a dedicated 110–120V, 20-amp grounded wall outlet. Extension cords and power strips are prohibited.
  • Hardwire: 3 wires from the appliance junction box — white (neutral), black (power L1), green (ground) — connected to a 120V circuit breaker panel. Junction box is located on the bottom left-hand, back-side of the unit. A qualified electrician must perform hardwire installation.
⚠️

Dedicated circuit required

The installation manual states: "DO NOT plug other appliances into the same circuit." The Orion Slim must be on its own dedicated circuit. Sharing a circuit with any other appliance is prohibited.

📏

Clearances to Combustibles

All measurements taken from the glass front — applies to all four models

Minimum Clearance Table — All Models

Direction Clearance Applies To
Bottom 0" All models
Sides 0" All models
Back 0" All models
Top (to mantel) 11.8" (300mm) All models
Top (to TV) 11.8" (300mm) All models
Top (to ceiling) 11.8" (300mm) All models
ℹ️

36" location clearance from combustibles

When selecting the installation location, the manual specifies: "Select a location that is not prone to moisture and is located at least 36" (914mm) away from combustible materials such as curtain drapes, furniture, bedding, paper, etc." This governs location selection — the 0" side and rear clearances in the table above govern the installed unit itself.

⚠️

3-foot operating clearance from front

During operation, the installation manual states: "Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3 feet (0.9m) from the front of the heater and keep them away from the sides and rear."

🔍

Size-by-Size Reference

All dimensions from the Modern Flames installation manual — fractions preserved as documented

OR52-SLIM — 52" Model

OR52-SLIM

Framing / Finished Opening

Framing W50-3/4"
Framing H19-1/8"
Framing D (min)6" min.

Overall Unit Dimensions

Overall W52-3/8"
Overall H19-5/8"
Overall D6-5/16"

Viewing Area

Viewing W47-7/8"
Viewing H14-3/8"

Electrical

Voltage120V only
Wattage1,465W
BTU Output5,000
Breaker20A dedicated

OR60-SLIM — 60" Model

OR60-SLIM

Framing / Finished Opening

Framing W58-1/2"
Framing H19-1/8"
Framing D (min)6" min.

Overall Unit Dimensions

Overall W60"
Overall H19-5/8"
Overall D6-5/16"

Viewing Area

Viewing W55-1/2"
Viewing H14-3/8"

Electrical

Voltage120V only
Wattage1,465W
BTU Output5,000
Breaker20A dedicated

OR76-SLIM — 76" Model

OR76-SLIM

Framing / Finished Opening

Framing W75-1/8"
Framing H19-1/8"
Framing D (min)6" min.

Overall Unit Dimensions

Overall W76-5/8"
Overall H19-5/8"
Overall D6-5/16"

Viewing Area

Viewing W72-3/16"
Viewing H14-3/8"

Electrical

Voltage120V only
Wattage1,465W
BTU Output5,000
Breaker20A dedicated

OR100-SLIM — 100" Model

OR100-SLIM

Framing / Finished Opening

Framing W99-1/2"
Framing H19-1/8"
Framing D (min)6" min.

Overall Unit Dimensions

Overall W101"
Overall H19-5/8"
Overall D6-5/16"

Viewing Area

Viewing W96-7/16"
Viewing H14-3/8"

Electrical

Voltage120V only
Wattage1,465W
BTU Output5,000
Breaker20A dedicated
View Orion Slim pricing and availability →
🛡️

Safety Restrictions

From the Modern Flames installation manual, Important Safety Information

⚠️ Indoor Use Only

"INDOOR use only! NEVER use this heater outdoors! Doing so may result in electric shock!"

  • "Use a dedicated 20 Amp (or higher) breaker."
  • "DO NOT plug other appliances into the same circuit."
  • "Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3 feet (0.9m) from the front of the heater and keep them away from the sides and rear."
  • "ALWAYS plug heaters directly into a wall outlet/receptacle. NEVER use with an extension cord or relocatable power tap (outlet/power strip)."
  • "NEVER use this heater in bathrooms, laundry rooms, or any other location where the heater could fall into a bathtub, pool, become damp, or come in contact with water."
  • "This product is not intended to be a primary heat source. It is for supplemental heat only."
  • "To prevent a possible fire, do not block air intakes or exhaust in any manner."
  • "ALWAYS mount to wall bracket before use. DO NOT set on the floor, or other surface, to use."
  • "NEVER use a wall mount bracket from another manufacturer."

Certifications

From the Modern Flames installation manual

  • CSA Listed. CSA C US, certification number 300773.
  • FCC Part 15 Class B. FCC ID: 2A7U3BOGERF. IC: 29298-BOGERF.
  • US Patent 11,473,745. Other patents may be pending in the US and other countries.

Frequently Asked Questions

All answers sourced from the Modern Flames installation manual

What is the minimum framing depth required for the Modern Flames Orion Slim?

All four Orion Slim models require a minimum framing depth of 6" (152mm). This applies uniformly across all four sizes. The overall unit depth is 6-5/16", so verify your wall or framing cavity accommodates at least 6" before ordering.

What installation types does the Modern Flames Orion Slim support?

The Orion Slim supports three installation types: wall recessed (slide-in into a framed opening), wall mounted (surface mount via bracket), and mantel installation. Freestanding use is explicitly prohibited — the unit must always be secured to a wall bracket before use.

What electrical circuit does the Modern Flames Orion Slim require?

All four models operate on 120V AC, 60Hz and draw 1,465W (5,000 BTU). A dedicated 20-amp (or higher) breaker is required. The circuit must be a dedicated grounded outlet — no other appliances may share the circuit. Extension cords and power strips are prohibited. No 240V option is available for the Orion Slim.

What is the minimum clearance above the Orion Slim glass front?

The minimum clearance from the glass front to any combustible material above — including a mantel, television, or ceiling — is 11.8" (300mm). All clearances are measured from the glass front. Side and rear installed clearances are 0".

What are the framing dimensions for each Orion Slim size?

OR52-SLIM: 50-3/4" W × 19-1/8" H. OR60-SLIM: 58-1/2" W × 19-1/8" H. OR76-SLIM: 75-1/8" W × 19-1/8" H. OR100-SLIM: 99-1/2" W × 19-1/8" H. All four models require a minimum framing depth of 6".

Is the Modern Flames Orion Slim approved for outdoor use?

No. The installation manual states: "INDOOR use only! NEVER use this heater outdoors! Doing so may result in electric shock!" All four models are rated for indoor use only.