SimpliFire Allusion Platinum Size Guide

Framing dimensions, electrical requirements, and clearances for the SF-ALLP50-BK, SF-ALLP60-BK, and SF-ALLP72-BK.

πŸ“‹

Overview

What this guide covers and how to use it

The SimpliFire Allusion Platinum is a recessed linear electric fireplace available in three sizes: 50 inches, 60 inches, and 72 inches. It installs into a finished 2x6 framed wall opening β€” the unit slides into the framed opening after wall finishing is complete, with the trim ring sitting flush against the finished wall surface.

This guide covers the framing dimensions, overall appliance dimensions, electrical requirements, and clearances needed to plan and execute a correct installation. All values are sourced from the SimpliFire installation manual.

ℹ️

2x6 Framing Required

The Allusion Platinum requires a minimum wall framing and finishing material thickness of 5-3/4 inches. It is not compatible with 2x4 framed wall construction. Plan framing before wall finishing begins.

πŸ“

Framing Requirements

All dimensions from the SimpliFire installation manual

Standard Recessed Installation (2x6 Framing)

Dimension SF-ALLP50-BK (50") SF-ALLP60-BK (60") SF-ALLP72-BK (72")
Framing Width 51" 61" 73"
Framing Height 19-5/8" 19-5/8" 19-5/8"
Wall Depth (framing + finish) 5-3/4" to 6-1/2" 5-3/4" to 6-1/2" 5-3/4" to 6-1/2"
Min. Wall Finish Thickness 5-3/4" 5-3/4" 5-3/4"
Max. Wallboard + Finish Combined 1" 1" 1"

Optional Framing β€” Discrete Outlet Location

An optional framing method allows the electrical outlet to be positioned discreetly within the wall cavity. This requires a wider framed opening.

Dimension SF-ALLP50-BK (50") SF-ALLP60-BK (60") SF-ALLP72-BK (72")
Extended Framing Width 62" 72" 84"
Framing Height 19-5/8" 19-5/8" 19-5/8"
Combined Wallboard + Finish 3/8" to 1" 3/8" to 1" 3/8" to 1"

⚠️ 2x4 Wall Construction β€” Not Compatible

This appliance is not intended to be recessed into 2x4 framed wall construction. A minimum wall framing and finishing material thickness of 5-3/4 inches is required. Consult local building codes before beginning framing.

πŸ“

Overall Appliance Dimensions

All dimensions from the SimpliFire installation manual

Overall dimensions include the front trim ring. Body-only dimensions (excluding trim) represent the chassis that sits within the framed opening.

Dimension SF-ALLP50-BK (50") SF-ALLP60-BK (60") SF-ALLP72-BK (72")
Overall Width (incl. trim) 52-5/16" 62-5/16" 74-5/16"
Overall Height (incl. trim) 20-7/16" 20-7/16" 20-7/16"
Overall Depth (side view) 19-3/8" 19-3/8" 19-3/8"
Body Width (excl. trim) 48" 58" 70"
Body Height (excl. trim) 15" 15" 15"
Body Depth (excl. trim) 5-5/8" 5-5/8" 5-5/8"
Mounting Width (bottom plate) 50-1/2" 60-1/2" 72-1/2"
⚑

Electrical Requirements

All electrical values from the SimpliFire installation manual

Specification Value β€” All Models
Voltage 120V AC
Frequency 60 Hz
Amperage 12.5 A
Wattage 1,500 W
Minimum Circuit Required 15A, 120V/60Hz
Dedicated Circuit Not required, but strongly recommended
Connection Options Hard-wired (120VAC, Type NM-B wire) or plug-in (NEMA 5-15P grounded receptacle)
GFCI Required Yes β€” if installed in a bathroom
⚠️

Extension Cords Prohibited

Never use an extension cord or relocatable power strip to power this appliance. Power supply service must be installed within proximity of the fireplace prior to finishing the wall to avoid reconstruction. All electrical connections must be performed by a qualified electrician and must comply with local building electrical codes and NFPA 70.

πŸ”₯

Clearances to Combustibles

All clearances from the SimpliFire installation manual β€” safety-critical values

Location Minimum Clearance β€” All Models
Sides 0 in.
Floor 0 in.
Top 0 in.
Back 0 in.
Front (combustibles from glass face) 36 in.
Mantel (above glass opening) 5/8 in.

Mantel Projection Clearances

Mantel Projection Depth Min. Clearance Above Glass Opening
Up to 24 in. 4 in.
Unlimited projection 4 in.

⚠️ Combustibles Clearance

Keep combustible materials β€” furniture, pillows, bedding, papers, clothes, decorations, and curtains β€” at least 3 feet (0.9 m) from the front of the appliance. This appliance is not intended for outdoor use. It is not water tight and must be installed away from showers, tubs, and other water sources.

πŸ”

Size-by-Size Reference

All dimensions from the SimpliFire installation manual

50-Inch Model

SF-ALLP50-BK
Framing W51"
Framing H19-5/8"
Framing D (min)5-3/4"
Overall W (w/ trim)52-5/16"
Overall H (w/ trim)20-7/16"
Overall D19-3/8"
Body W (excl. trim)48"
Body H (excl. trim)15"
Body D (excl. trim)5-5/8"
Alt. Framing W (discrete outlet)62"
View Allusion Platinum pricing and availability β†’

60-Inch Model

SF-ALLP60-BK
Framing W61"
Framing H19-5/8"
Framing D (min)5-3/4"
Overall W (w/ trim)62-5/16"
Overall H (w/ trim)20-7/16"
Overall D19-3/8"
Body W (excl. trim)58"
Body H (excl. trim)15"
Body D (excl. trim)5-5/8"
Alt. Framing W (discrete outlet)72"
View Allusion Platinum pricing and availability β†’

72-Inch Model

SF-ALLP72-BK
Framing W73"
Framing H19-5/8"
Framing D (min)5-3/4"
Overall W (w/ trim)74-5/16"
Overall H (w/ trim)20-7/16"
Overall D19-3/8"
Body W (excl. trim)70"
Body H (excl. trim)15"
Body D (excl. trim)5-5/8"
Alt. Framing W (discrete outlet)84"
View Allusion Platinum pricing and availability β†’
❓

Frequently Asked Questions

All answers sourced from the SimpliFire installation manual

What framing size does the SimpliFire Allusion Platinum require?

The Allusion Platinum requires 2x6 framed wall construction. Framing widths are 51 inches for the 50-inch model, 61 inches for the 60-inch model, and 73 inches for the 72-inch model. Framing height is 19-5/8 inches for all three sizes. Wall framing and finishing material must be a minimum of 5-3/4 inches thick. This appliance is not intended for recessed installation into 2x4 framed wall construction.

What is the minimum wall depth required for the SimpliFire Allusion Platinum?

The Allusion Platinum requires a minimum wall framing and finishing material thickness of 5-3/4 inches. The appliance body depth (excluding trim) is 5-5/8 inches. Combined wallboard sheathing and finishing material thickness must be between 3/8 inch and 1 inch. A standard 2x6 framed wall meets this requirement; 2x4 framed walls do not.

What are the overall dimensions of the SimpliFire Allusion Platinum including the trim?

Overall dimensions including the front trim are: 50-inch model β€” 52-5/16 inches wide by 20-7/16 inches tall by 19-3/8 inches deep. 60-inch model β€” 62-5/16 inches wide by 20-7/16 inches tall by 19-3/8 inches deep. 72-inch model β€” 74-5/16 inches wide by 20-7/16 inches tall by 19-3/8 inches deep.

What electrical circuit does the SimpliFire Allusion Platinum require?

The Allusion Platinum requires a minimum 15-amp, 120V/60Hz circuit. It draws 12.5 amps at 1,500 watts. A dedicated circuit is not required but is strongly recommended to prevent circuit breaker trips. The appliance can be hard-wired using Type NM-B wire or connected via the included power cord to a grounded NEMA 5-15P receptacle. Extension cords and relocatable power strips must not be used.

What are the clearance requirements for the SimpliFire Allusion Platinum?

Minimum clearances to combustible construction are: sides 0 inches, floor 0 inches, top 0 inches, back 0 inches, front 36 inches, mantel 5/8 inch. For mantel projections up to 24 inches, a minimum of 4 inches of clearance above the glass opening is required. Combustible materials such as furniture, pillows, bedding, and curtains must be kept at least 3 feet from the front of the appliance.

Can the SimpliFire Allusion Platinum be installed outdoors?

No. The SimpliFire Allusion Platinum is rated for indoor use only. The installation manual states explicitly: do not use outdoors. The appliance is not water tight and must be installed away from showers, tubs, and other water sources. If installed in a bathroom, GFCI protection is required.